230 & 460 Volt Models
12 Lead Motor Required
For 230 Volt Operation Motor must be Wye (Star) Wound 12 Leads
For 460 Volt Operation Motor may be either Wye (Star) or Delta Wound 12 Leads
The H-A-S Static Phase Converter allows three phase motors to operate on single phase power. The H-A-S Static Phase Converter does not produce three phase power, instead through its special connection diagram with a 12 lead motor, it converts a three phase motor into what is known as an unbalanced two phase motor. This conversion process has been successful with thousands of motor applications. But due to its technical requirements, (i.e. 12 leads, 230/460 dual voltage winding, etc.), it cannot be applied to all three phase motors. Some foreign made motors are designed with different alloys or maybe wound differently, which can cause a problem in mating with this type converter. Submersible pump motors with sealed windings cannot accomodate the 12 lead requirement. On applications such as these, the Rotary Phase Converter is the best choice.